Zipper closure 1/4 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
PRODUCT NAME

(UL & CE) UL2586(P) 105°C 600V Copper core PVC sheathed and insulated power cable (shielded)

PRODUCT APPLICATION

UL & CUL listed PVC cables, PVC wiring cables for internal wiring in control cabinets, medical technology equipment, electronic components and controls, as well as for installation in protective hoses and ducts in mechanical engineering and for use as connecting cables for transformers and motors as flexible shielded power and control cables, external interconnections or internal wiring, for EMC-compliant connections for high electrical and light and medium mechanical requirements in motion drive systems in machine and plant engineering.

PRODUCT CHARACTERISTIC

RoHS compliant

TECHNICAL APPROVALS

UL & CUL compliant, UL758, CSA C22.2 No.210

2014/35/EU-guidelines (Low Voltage Directive)CE

Customized products are accepted for special structures, other sizes, colours of cores and jackets.

PRODUCT STRUCTURE

Conductor material: bare copper

Conductor type: UL758, ASTM B3 or ASTM B33, DIN VDE 0295 Class 5 conductor or IEC 60228 Class 5 conductor

Core insulation: PVC, XLPE, TPE (optional)

Core identification: black with white numbering according to DIN VDE 0293, 1 x GNYE

Rated voltage: 1000 V

Cable formation: core stranded or in parallel construction

Shielding: Braided tinned copper wire shield, shielding density >70°C

Sheath: PVC

Jacket colour: grey RAL7001 or black RAL9005

Test voltage: 3000V

Conductor resistance: UL1581 ASTM Class C

Insulation resistance: PVC: +20℃≥20MΩ x km; XLPE: +20℃≥20MΩ x km

Minimum bending radius fixed laying value: 4x d

Minimum bending radius moving laying value: 10x d

Operating temperature: fixed small/large value: -40°C/+80°C

Operating temperature: mobile small/large value: -30°C/+80°C

Flame retardant grade: self-extinguishing and flame retardant in accordance with UL1581VW-1; CSA C22.2 No.2556-15 FT1, FT2; IEC 60332-1-2 standards

Certification: UL & CUL: UL1015, UL10914, UL11122, UL3271, UL3321, UL3196, UL3289, UL3237, UL3820, UL2586

      CE: YSLCY, 2XSLCY (CE certification requirements need to be indicated separately)