description1
Zipper closure 1/4 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
PRODUCT NAME

(CE)YSLYCY Copper core PVC sheathed and insulated oil resistant cable

PRODUCT APPLICATION

power, control and connection cables in electric utilities, for data and signal transmission in environments where resistance to electromagnetic interference is required, for fixed laying or other mobile applications. The cables are suitable for dry, damp and wet indoor use.

PRODUCT CHARACTERISTIC

Acid and alkali resistant, oil resistant; inner sheath cable structure can enhance the protection of the cable, in line with EMC requirements, has good chemical resistance.

TECHNICAL APPROVALS

RoHS compliant   2014/35/EU (Low Voltage Directive) CE

Special structure, other sizes, core and sheath colour products can be customized.

PRODUCT STRUCTURE

Conductor material: bare copper wire

Conductor type: in accordance with IEC60228 cl.5 standard

Core insulation: PVC-J-80-005

Core identification: <0.5mm²: 5 cores and below with colour separation, in accordance with n.DIN 47100, above 5 cores multi-core cables with colour separation of core wires, differentiated by white ink dots; ≥0.5mm²: 5 cores and below with colour separation, with yellow/green ground, in accordance with n.DIN 47100, above 5 cores multi-core cables with black core wires, differentiated by white ink numbering (if any) special requirements on request)

Stranding: Stranded in layers

Inner jacket: PVC

Shield: Tinned copper braid with approx. 80% coverage

Outer jacket material: DQPVC-H-80-005

Outer sheath colour: transparent

Rated voltage: 300/500V

Test voltage: 2kV

Conductor resistance: Conforms to IEC 60228 cl.5 standard

Insulation resistance: 20MΩ x km

Minimum bending radius fixed laying value: 6x d

Minimum bending radius moving laying value: 20x d

Temperature rating fixed value: -40°C/+80°C

Temperature class moving value: -5°C/+80°C

Temperature: +70°C operating temperature;     +150°C short-circuit temperature

Standard: Conforms to EN 50525-2-51| 0.6/1kV

Type: Insulation thickness 1KV standard thickness